Wholesale China Fetal Heart Rate Monitor Hospital Factory Suppliers - Pulse Oximeter YK82K – Binic
Wholesale China Fetal Heart Rate Monitor Hospital Factory Suppliers - Pulse Oximeter YK82K – Binic Detail:
Parameter
Model:YK82K Weight: 20.2g
Range(SpO2): 70%~100% Resolution 1%
Range(PR): 30~240bpm Accuracy: ±2%(80%~99%)
Resolution: 1bpm Accuracy: ±1bpm
Product Features
Suitable for children 1-12 years old
2 color OLED display, automatic test
8 seconds without finger, device will automatically shut down
Medical clinical level settings
Lithium battery, rechargeable
Can support long-term use without frequent battery replacement
data lines, no positive or negative insertion/ Equipped with the popular type-c interface, fre
cause confusion to you, provide a more convenient experience.
A cute cartoon series lanyard is provided for children to wear around the neck and protect their health in real time
YK82K Pediatric Cartoon Series Fingertip Pulse Oximeter
The YK82K Pediatric Cartoon Series Fingertip Pulse Oximeter can detect the Sp-02, Pulse Rate, Pulse Wave and Pulse Histogram in real time and display them on the OLED screen. The abnormal value warning function provides parents with peace of mind.
Easy to monitor
You can accurately check your child’s physical condition in 3 seconds. There is no need to go to the hospital for blood collection, no need to bear the pain of skin and flesh, as long as the finger is gently clamped.
Child’s guardian—The abnormal value warning function.
When the child’s O2 level is lower than 88%, or the pulse rate is lower than 40bpm/higher than 120bpm, the corresponding readings on the oximeter screen will flash to remind you.
Accurate & Reliable
It can monitor your child’s physical data accurately and non-invasively. YK82K Pediatric Cartoon Series Fingertip Pulse Oximeter has strong technical support, using red/R light and near-infrared light as the incident light source. The device can calculate SP-02, pulse rate, pulse wave and PI.
How to use?
Step 1
We recommend index finger, middle finger and ring finger are suitable position for monitor. |
Step 2
Press the bottom to open the probe. |
Step 3
Insert the finger into the bottom of machine. |
Step 4
Press the operating button to activate the oximeter. |
Product detail pictures:
Related Product Guide:
Being supported by an innovative and experienced IT team, we could present technical support on pre-sales & after-sales service for Wholesale China Fetal Heart Rate Monitor Hospital Factory Suppliers - Pulse Oximeter YK82K – Binic, The product will supply to all over the world, such as: France, European, Cambodia, We also have good cooperation relationships with many good manufacturers so that we can provide almost all of auto parts and after-sales service with high quality standard,lower price level and warmly service to meet demands of customers from different fields and different area.